Presently, we supply different series for local customer requirements and design
updated incinerator with our leading technology. The updated design feature
of our range of incinerators make them one of the most cost effective in the world.
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime.
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day.
* PLC Control Plane for Intelligent operation.
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
It features unique and advanced merits with compact size, high burning effect,
reasonable burning technology, high degree of non-harm etc.It is an ideal
choice for waste treatment of hospitals, hotels and various areas.
Features:
(5) Compact structure and small land occupation.
Nanjing Clover Medical Technology Co.,Ltd.
(1) Gasifiedpyrolysis incineration is used for burning many Types of waste.
Items/Model |
TS10(PLC) |
TS20(PLC) |
TS30(PLC) |
TS50(PLC) |
TS100(PLC) |
Burn Rate (Average) |
10 kg/hour |
20 kg/hour |
30 kg/hour |
50 kg/hour |
100 kg/hour |
Feed Capacity(Average) |
20kg |
40kg |
60kg |
100kg |
200 kg |
Control Mode |
PLC |
PLC |
PLC |
PLC |
PLC |
Combustion Chamber |
100L |
210L |
330L |
560L |
1200L |
Internal Dimensions |
50x50x40cm |
65x65x50cm |
75x75x60cm |
100x80x70cm |
120x100x100cm |
Secondary Chamber |
50L |
110L |
180L |
280L |
600L |
Smoke Filter Chamber |
Yes |
Yes |
Yes |
Yes |
Yes |
Feed Mode |
Manual |
Manual |
Manual |
Manual |
Manual |
Voltage |
220V |
220V |
220V |
220V |
220V |
Power |
0.5Kw |
0.5Kw |
0.5Kw |
0.7Kw |
0.7Kw |
Oil Consumption (kg/hour) |
5.4–12.6 |
7.8–16.3 |
10.2–20 |
12.1–24 |
14–28 |
Gas Consumption (m3/hour) |
6.2–11.4 |
8–15.7 |
9.8–20 |
9.9–26.1 |
10–32.2 |
Temperature Monitor |
Yes |
Yes |
Yes |
Yes |
Yes |
Temperature Protection |
Yes |
Yes |
Yes |
Yes |
Yes |
Oil Tank |
100L |
100L |
100L |
100L |
200L |
Feed Door |
30x30cm |
45x40cm |
55x50cm |
70x55cm |
80x60cm |
Chimney |
3Meter |
3Meter |
5Meter |
5Meter |
10Meter |
Chimney Type |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
1st. Chamber Temperature |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
2nd. Chamber Temperature |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
Gross Weight |
1500kg |
2200kg |
3000kg |
4500kg |
6000kg |
External Dimensions |
140x90x120cm |
160x110x130cm |
175x120x140cm |
230x130x155cm |
260x150x180cm |
Tel: +86-25-8461 0201
PRIMARY CHAMBERHeavy-duty steel casingHigh quality refractory lining and insulation Large full size top load counterbalanced door1 x oil/gas fired ignition burners operated on/off
SECONDARY CHAMBERHeavy-duty steel casingHigh quality refractory lining and insulation 2 second gas residence time1 x oil/gas fired ignition burners operated on/off
CHIMNEYHeavy-duty stainless steel casing
Thermostat control device for burner (fuel saver) Timer
control 0- 12 hours
Integral fan timer control
CONTROL PANELControl of primary and secondary burners Temperature Monitoring with 4 digit display
ANCILLARIESOperating and maintenance manuals Spares list
KEY FEATURES
•Afterburner Preheat
•Incineration temperatures in excess of 1300°C
•5mm steel casing and completely insulate
•Dense refractory concrete lining ranked to 1600°C
The regulated sections may include but not limited to:
An approved plant must have four different sections that demonstrate three principles ofTurbulence, Residence Time and Temperature are inbuilt in the plant design.
Overall plant layout. Feed chamber/ chargingPrimary Combustion Chamber. Secondary Combustion Chamber. Particulate ScrubbersAcid Gas Scrubbers The stack/ chimney.Controlled hygienic, mechanical or automatic feeding methods have to be used whichwill not influence the air temperature in the primary and secondary chambers of the incinerator negatively.
No waste is to be fed to the incinerator:
1. If the minimum combustion temperatures are not maintained.3. Whenever the previous charge has not been completely combusted in the case of batch feeding.4. Until such time as the addition of more waste Won’t cause the layout parameters of the incinerator to be exceeded.The primary combustion chamber should:
Other combustion methods will be judged on merits.
1. Be equipped with a burner/s burning gas/fuel or low sulphur liquid fuels.
3. Ensure main air supply is controlled efficiently
4. Ensure minimum exit temperature is not less than 850oCThe secondary combustion chamber should:
1. Be accepted as secondary combustion zone.2. Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any Appropriate fuel.
chamber & not in the flame zone, is not less than
1100oC.
7. Ensure the oxygen content of the emitted gases is not less than 11%.
8. Ensure both primary and the combustion temperatures are maintained
until all waste has been completely combusted
A mechanical particulate collector must be incorporated after secondary combustion
chamber for removal of particulate pollutants entrained in the flue gas stream.
The particulate collectors may include any of the following or
a combination thereof:
Cyclone separator Electrostatic precipitators Fabric filters
-
-
3. Ensure secondary air supply is controlled efficiently.4. Make sure fire contact with all gases is achieved.5. Ensure residence time is not less than two (2) seconds.6. Ensure the gas temperature as measured against the inside wall at the secondary
[ecwid widgets="productbrowser search categories"
default_category_id="CATEGORY_ID"
default_product_id="PRODUCT_ID" lang="EN"]